en:3s:hw [2020/08/10 07:15] – [Wiring] goran.kocjancicen:3s:hw [2020/08/10 07:46] (current) – [Wiring] goran.kocjancic
Line 5: Line 5:
 ===== Wiring ===== ===== Wiring =====
  
-^ Device                        ^  Power supply     ^  Conected to             || +^ Device                        ^  Power supply     ^  Conected to               || 
-| TOF sensor                    | POE               |  MC     | GND, IX0, IX1   | +| TOF sensor                    | POE               |  MC     | GND, IX0, IX1     | 
-| Temperature and mask scanner  | PS: 12 VDC        |  MC     | GND, IX2        | +| Temperature and mask scanner  | PS: 12 VDC        |  MC     | GND, IX2          | 
-| QR and RFID reader            | CR-W2: +12V, GND  |  CR-W2  | D0, D1-0, GN-0  | +| QR and RFID reader            | CR-W2: +12V, GND  |  CR-W2  | D0, D1-0, GN-0    | 
-| Entrance allowed              | -                 |  CR-W2  | C1 - QX0        | +| Entrance allowed              | -                 |  CR-W2  | C0 - QX0 (Relay)  | 
-| REED entrance                 | -                 |  CR-W2  | GND - IW0       | +| REED entrance                 | -                 |  CR-W2  | GND - IW0         | 
-| Button entrance               | -                 |  CR-W2  | GND - IW1       | +| Button entrance               | -                 |  CR-W2  | GND - IW1         | 
-| Exit allowed                  | -                 |  CR-W2  | C2 - QX1        | +| Exit allowed                  | -                 |  CR-W2  | C0 - QX1 (Relay)  | 
-| REED exit                     | -                 |  CR-W2  | GND - IW2       | +| REED exit                     | -                 |  CR-W2  | GND - IW2         | 
-| Button exit                   | -                 |  CR-W2  | GND - IW3       | +| Button exit                   | -                 |  CR-W2  | GND - IW3         | 
-| Motion sensor                 | MC: +24V, GND     |  MC     | IX0             | +| Motion sensor                 | MC: +24V, GND     |  MC     | IO12              | 
-| Hand disinfection             | EXT:              |  MC     | GND - IO14      | +| Hand disinfection             | EXT:              |  MC     | GND - IO15        | 
-| Alarm                         | PS: 12 VDC        |  MC     | QX0             | +| Alarm                         | PS: 12 VDC        |  MC     | C1 - QX2 (Relay)  | 
-| LED Display                   | EXT: 230 VAC      |  MC     | TxD, RxD, GND   |+| LED Display                   | EXT: 230 VAC      |  MC     | TxD, RxD, GND     |
  