-====== Single phase power-meter ====== 
- 
-**Single phase power-meter** 
- 
-<WRAP column 350px> 
- 
-{{ hiq_energy:goflex_hems:hardware:sdm120c.png?nolink |}} 
- 
-</WRAP> 
- 
-<WRAP column 300px> 
- 
-| Model number: ^ PM1-E-D                             | 
-| Mounting:     | DIN rail, 1M, 18 mm                 | 
-| Dimensions:   | 18 × 62 × 119 mm                    |  
- 
-^ Used for measuring power and energy of                 || 
-| ✔ | single-phase energy sources                        | 
-| ✔ | single-phase energy consumers                      | 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
-===== Applications ===== 
- 
-  * Digital multi-function energy meter for single phase networks 
- 
-===== Features ===== 
- 
-  * DIN rail mounting with direct connection up to 45A 
-  * Compact design in a single module 18mm wide 
-  * Seal-able cover(phase and neutral terminals) 
- 
-===== General description ===== 
- 
-The PM1-E-D series is an advanced single phase energy monitoring solution with built-in configuration push button and LCD data displaying, particularly indicated for active energy and other parameters metering and for cost allocation. Housing for DIN-rail mounting,IP51 protection degree, direct connection up to max 45A. 
- 
- 
-<WRAP pagebreak></WRAP> 
- 
-===== Technical specifications ===== 
- 
-|< 35% 40% >| 
-| Nominal voltage(Un)                       230 VAC| 
-| Operational voltage                     176-276 V| 
-| Insulation capabilities                           ||         
-| - AC voltage withstand        |   4 KV for 1 minute| 
-| - Impulse voltage withstand           6 kV-1.2 µS| 
-| Basic current (Ib)            |                 5 A| 
-| Maximum rated current (Imax)  |                45 A| 
-| Operational current range            0.4% Ib-Imax| 
-| Over current withstand        |  20 Imax for 0.01 s| 
-| Operational frequency range           50 or 60 Hz| 
-| Internal power consumption    |         ≤ 2 W/10 VA| 
-| Communication type            |  RS485(half-duplex)| 
-| Communication protocol        |          Modbus RTU| 
-| Pulse output 1                |        configurable| 
-| Pulse output 2                |        1000 imp/kWh| 
-| Max reading                           99999.9 kWh| 
- 
-===== SDM120 Terminals ===== 
- 
-<WRAP column 75%> 
- 
-|< 50% 30% 10% 10% >| 
-^    PM1-E-D                       ||^   Power source   | 
-| Phase IN          |  L↑      |                  | 
-| Neutral            N    |    |                  | 
- 
-|< 50% 30% 10% 10% >| 
-^    PM1-E-D                       ||^  Power consumer  | 
-| Phase OUT          L↓      |    L               | 
- 
-|< 75% 27% 7% 33% >| 
-^  PM1-E-D                         |^  CAD-232-A2-IQ  ^  BR-WN-W  
-| RS485                      8        C          |    GND     | 
-| :::                        9        B          |   Tx/T-    | 
-| :::                        10  |      A          |   Rx/T+    | 
- 
- 
-</WRAP> 
- 
-<WRAP column 20%> 
- 
-{{hiq_hardware:sdm120c-io.png?nolink}}  
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
-{{ hiq_hardware:eastron_sdm120-modbus_user_manual_2016_v2_6.pdf | PM1-E-D user manual}} 
- 
-{{ hiq_hardware:sdm220modbus_protocol_v1.1.pdf | PM1-E-D Modbus protocol}} 
- 
-<WRAP pagebreak></WRAP> 
  
en/goflex_hems/hardware/pm1-e-d.1538746350.txt.gz · Last modified: 2018/10/05 13:32 by goran.kocjancic