-====== Three phase power-meter ====== 
- 
-**Three phase power-meter** 
- 
-<WRAP column 350px> 
- 
-{{ hiq_energy:goflex_hems:hardware:pm3-i-d.png?nolink |}} 
- 
-</WRAP> 
- 
-<WRAP column 300px> 
- 
-| Model number: ^ PM3-I-D                       | 
-| Mounting:     | DIN rail, 3M, 53 mm           | 
-| Dimensions:   | 53 × 84 × 66 mm                
- 
-^ Used for measuring power and energy of                || 
-| ✔ | three-phase energy sources                        | 
-| ✔ | three-phase energy consumers                      | 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
-===== Applications ===== 
- 
-  * Digital multi-function energy meter for 3-phase sources or consumers 
- 
-===== Features ===== 
- 
-  * Three phase direct connection up to 65 A 
-  * Serial RS485 communication 
-  * Display LCD 7+1 digit 
-  * Multi-functional front LED 
- 
-===== General description ===== 
- 
-The PM-3-IQ is intended for energy measurements in three-phase electrical power network and can be used in residential, industrial and utility applications. Meter measures energy directly in 4-wire networks according to the principle of fast sampling of voltage and current signals. 
- 
-Connecting terminals can be sealed up against non-authorized access with protection covers. They are built to be fastened according to EN 60715 standard. Meter has built-in  RS485 serial communication with the MOD-BUS protocol which enables data transmission and thus connection of the measuring places into the network for the control and management with energy. 
- 
-<WRAP pagebreak></WRAP> 
- 
-===== Technical specifications ===== 
- 
-|< 35% 40% >| 
-| Nominal voltage                3x230/400 VAC (-20..+15%) | 
-| Power connector                 1,5 .. 16 mm<sup>2</sup> |         
-| Reference current                                    5 A | 
-| Maximum current                                     65 A | 
-| Operational frequency range                   50 or 60 Hz| 
-| Internal power consumption    |                     < 8 VA | 
-| Communication type            |         RS485(half-duplex) | 
-| Communication protocol        |                 Modbus RTU | 
-^ Accuracy                                                  || 
-| Active energy (Wh)            |       Class 1 IEC 62053-21 | 
-| :::                                   class B EN 50470-3 | 
-| :::                               ±1.5% from Imin to Itr | 
-| :::                                 ±1% from Itr to Imax | 
-^ Ambient conditions and Safety                             || 
-| Dust/water protection                               IP50 | 
-| Operating temp. range                       -25 ... 55°C | 
-| Indoor meter                  |                        yes | 
-| Protection class              |                         II | 
-^ EC Directives conformity                                  ||    
-|          EC Directive on Measuring Instruments 2014/32/EU || 
-|                            EC Directive on EMC 2014/30/EU || 
-|                    EC Directive on Low Voltage 2014/35/EU || 
-|                              EC Directive WEEE 2002/96/EC || 
- 
-===== Terminals ===== 
- 
-<WRAP column 70%> 
- 
-|< 50% 30% 10% 10% >| 
-^    PM3-I-D                       ||^   Power source   | 
-| Phase 1 IN          |  L1↑  |    |     L1           | 
-| Phase 2 IN          |  L2↑  |    |     L2           | 
-| Phase 3 IN          |  L3↑  |    |     L3           | 
-| Neutral              N    |  10  |                | 
- 
-|< 50% 30% 10% 10% >| 
-^    PM3-I-D                       ||^  Power consumer  | 
-| Phase 1 OUT          L1↑  |    |    L1            | 
-| Phase 2 OUT          L2↑  |    |    L2            | 
-| Phase 3 OUT          L3↑  |    |    L3            | 
-| Neutral              N    |  11  |    N             | 
- 
-|< 75% 27% 7% 33% >| 
-^  PM3-I-D                        |^  CAD-232-A2-IQ  ^  BR-WN-W  
-| RS485                      16  |      A          |   Rx/T+   | 
-| :::                        15  |      B          |   Tx/T-   | 
- 
-</WRAP> 
-<WRAP clear></WRAP> 
-<WRAP pagebreak></WRAP> 
- 
- 
-===== Connection ===== 
- 
-{{:hiq_energy:hems:hardware:pm3_terminals.png?nolink |}} 
-===== Manual ===== 
- 
-{{ hiq_energy:goflex_hems:hardware:wm3-6-tehnicna-dokumentacija-ver-1.04.pdf | PM3-I-D Technical Documentation}} 
- 
  
en/goflex_hems/hardware/pm3-i-d.1543394108.txt.gz · Last modified: 2018/11/28 08:35 by saso_santelj