en:hems_v1_2_0:introduction [2021/11/22 12:43] saso_santeljen:hems_v1_2_0:introduction [2021/11/22 12:59] (current) saso_santelj
Line 23: Line 23:
 and units to be connected on it. Units can be divided on input and output:  and units to be connected on it. Units can be divided on input and output: 
   * from **input**, controller gets measured values e.g. from different sensors (power sensor-PS, temperature) or ON/OFF signals from thermostat, switches, push buttons, while   * from **input**, controller gets measured values e.g. from different sensors (power sensor-PS, temperature) or ON/OFF signals from thermostat, switches, push buttons, while
-  * on **output**, controller applies result of control algorithm e.g. with power relays switches ON/OFF devices (water heater, washing machine, dryer..) or set charging current for EV on charging station or set charge/discharge current on storage system.+  * on **output**, controller applies result of control algorithm e.g. with power relays switches ON/OFF devices (water heater, heat pump, washing machine...) or set charging current for EV on charging station or set charge/discharge current on storage system.
  
 **HEMS supports**: **HEMS supports**:
   ✔ 1 grid power sensor   ✔ 1 grid power sensor
-  ✔ up to 3 sensors for local power plants (PV, Wind, Cogeneration, Generator, etc) - as SOURCES+  ✔ up to 3 local power plants (PV, Wind, Cogeneration, Generator, etc) - as SOURCES
   ✔ up to 2 local storage systems (home battery) - as CONSUMER OR SOURCE   ✔ up to 2 local storage systems (home battery) - as CONSUMER OR SOURCE
   ✔ up to 8 devices (electrical heating, EV charging station, electrical domestic water heater, washing machine, tumble dryer, …) as CONSUMERS.   ✔ up to 8 devices (electrical heating, EV charging station, electrical domestic water heater, washing machine, tumble dryer, …) as CONSUMERS.
  
-In terms of HEMS terminology there are devices producing energy (PV) named as **sources** and devices consuming energy named **consumers**. For both types, measured electrical characteristic are provided by power meter sensor connected to this device. Consumers could be defined as: +In terms of HEMS terminology there are devices producing energy (i.e. PV) named as **sources** and devices consuming energy named **consumers**. For both types, measured electrical characteristic are provided by power sensor connected to this device. Consumers can be defined as: 
-  - Power sensor connected to measured device without capability of control (just measuring),  +  - Power sensor connected to measured device without capability of control (just measuring),  
-  - Power sensor connected to measured device with capability of control (HEMS is in charge of controlling a device), +  - Power sensor connected to measured device with capability of control (HEMS is in charge of controlling a device), 
-  - Managed device connected to controller without power sensor but with the default set nominal power for device, +  - Managed device connected to HEMS without power sensor but with the default set nominal power for device, 
-  - Managed device connected to controller without power sensor and without set default nominal power.+  - Managed device connected to HEMS without power sensor and without set of default nominal power.
  
-For connection on cloud HEMS is using IOT linker device. +For connection to cloud HEMS is using IOT linker device. 
  
-Below is illustrated HEMS scheme. Connection between controller and units could be **wired** (directly on port, modbus RTU/TCP) or **wireless** (using EnOcean protocol or [[en:hiq_hw:wm-1|wireless modbus to modbus bridge]]):+Below is illustrated HEMS scheme. Connection between controller and units can be **wired** (directly on port, modbus RTU/TCP) or **wireless** (using EnOcean protocol or [[en:hiq_hw:wm-1|wireless modbus to modbus bridge]]):
  
 {{:hiq_energy:hems_v1_2_0:HEMS_intro.png?direct&600|}} {{:hiq_energy:hems_v1_2_0:HEMS_intro.png?direct&600|}}
Line 45: Line 45:
 where: where:
   * temperature sensor is  directly wired ([[en:hiq_hw:es|Digital temperature sensor]]) or paired ([[en:hiq_hw:en-ts-iq|Wireless temperature sensor]] and [[en:hiq_hw:en-tsh-iq|Wireless temperature and humidity sensor]] ) to the HEMS master controller [[en:hiq_hw:mc-230|MC-230]]. **Note**: only one temperature sensor can be added,   * temperature sensor is  directly wired ([[en:hiq_hw:es|Digital temperature sensor]]) or paired ([[en:hiq_hw:en-ts-iq|Wireless temperature sensor]] and [[en:hiq_hw:en-tsh-iq|Wireless temperature and humidity sensor]] ) to the HEMS master controller [[en:hiq_hw:mc-230|MC-230]]. **Note**: only one temperature sensor can be added,
-  * measurement of electrical power and energy is provided by single-phase ([[en:hiq_hw:pm1-e-d|PM1-E-D]]) or three-phase ([[en:hiq_hw:pm3-i-d|PM3-I-D]] and [[en:hiq_hw:pm3-e-d-ct|PM3-E-D]]) power sensors which are connected directly to HEMS master controller [[en:hiq_hw:mc-230|MC-230]] or they could be connected wirelessly using WM-1 wireless modbus unit. +  * measurement of electrical power and energy is provided by single-phase ([[en:hiq_hw:pm1-e-d|PM1-E-D]]) or three-phase ([[en:hiq_hw:pm3-i-d|PM3-I-D]] and [[en:hiq_hw:pm3-e-d-ct|PM3-E-D]]) power sensors which are connected directly to HEMS master controller [[en:hiq_hw:mc-230|MC-230]] or they could be connected wirelessly using [[en:hiq_hw:wm-1|WM-1]] wireless modbus unit. 
   * there are also wireless modules [[en:hiq_hw:en-p1-iq|Metering smart plug]] and [[en:hiq_hw:en-p2-iq|Micro smart plug]] with integrated power sensor to measure consumption and power of consumer,    * there are also wireless modules [[en:hiq_hw:en-p1-iq|Metering smart plug]] and [[en:hiq_hw:en-p2-iq|Micro smart plug]] with integrated power sensor to measure consumption and power of consumer, 
-  * power relays are used for control of managed consumers. They are toggling power supply or enabling signals for the operation of the device. Supported connection is as wired as wireless ([[en:hiq_hw:en-rs2-iq|wireless relay switch]])+  * power relays are used for control of managed consumers. They are toggling power supply or enabling signals for the operation of the device. Supported connection is as wired relay or as [[en:hiq_hw:en-rs2-iq|wireless relay switch]], 
-  * push button are used for manual control of managed devicesand are directly wired or paired ([[en:hiq_hw:en-sr-iq|Soft remote]]) to HEMS master controller.+  * push button are used for manual control of managed devices and are directly wired to HEMS master controller.
  
  