 ===== CyBroBinLoader software ===== ===== CyBroBinLoader software =====
-  * Download latest CyBroBinLoader.exe from www.cybrotech.com+  * Download latest CyBroBinLoader.exe from https://www.cybrotech.com/software-category/tools/ 
 +  * Run CybroBinLoader.exe 
 +  * In case Windows OS is blocking execution, click on "more info" and "run anyway" 
  
-{{ hiq_energy:hems_v1_2_0:cybrobinloader.png?nolink&0x120        }}+{{ hiq_energy:hems_v1_2_0:cybrobinloader.png?nolink&0x140        }}
  
 <WRAP clear></WRAP> <WRAP clear></WRAP>
Line 12: Line 14:
 <WRAP pagebreak></WRAP> <WRAP pagebreak></WRAP>
  
-===== Applications =====+===== Firmware upload =====
  
-  * Replacement for RS485 wiring solution with wireless. Optimal for long range Modbus RTU serial communications with half duplex configuration.+  * Download latest HEMS firmware from [[en:hems_v1_2_0:download|Download]] 
 +  * Select correct Cybro NAD (sticker on top or side of MC controller) 
 +  * Select firmware under PLC program 
 +  * Enable PLC program and Start PLC 
 +  * Click send 
 +  * :!: PC must be on the same network as MC controller 
 +  * :!: Do not interrupt durring update process 
 +  * :!: HEMS configuration may be lost, use BACKUP before update and later RESTORE as described under [[en:hems_v1_2_0:software#settings|Software]] 
 +  
 +{{ hiq_energy:hems_v1_2_0:cybrobinloader_selectnad.png?nolink }} 
 + 
 +{{ hiq_energy:hems_v1_2_0:cybrobinloader_firmware.png?nolink }}
  
-</WRAP> 
  
 <WRAP clear></WRAP> <WRAP clear></WRAP>
- 
-===== Installation and mounting ===== 
-  * :!: Carefully open WM-1 module and configure serial communication with jumpers. (Default configuration is 9600bps, 8N1 with normal timeout) 
-  * :!: Place WM-1 module at least 10cm from other objects. Installation is not recommended inside metal cabinets. 
-  * Connect RS485 terminals to WM-1 RS485 terminals 
-    * A - A 
-    * B - B 
-    * C - GND 
-  * Connect to 230V power supply 
-  * Configure radio pairing 
- 
-{{ hiq_hardware:wm1_module_diagram.png?nolink&0x500  }} 
-{{ hiq_hardware:wm1_mounting.png?nolink&0x500  }} 
- 
-<WRAP pagebreak></WRAP> 
- 
-===== Features ===== 
- 
-  * replacement for RS485 wiring 
-  * Modbus RTU serial protocol 
-  * wired/wireless combinations 
-  * very long range, no hopping 
-  * protected private connection 
-  * multiple slaves per device 
-  * multiple addressable groups 
  
  