en:hems_v1_2_0:methods_resources:firmwareupdate

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
en:hems_v1_2_0:methods_resources:firmwareupdate [2021/10/28 09:37] neoxyen:hems_v1_2_0:methods_resources:firmwareupdate [2021/10/28 13:22] (current) neoxy
Line 4: Line 4:
  
 ===== CyBroBinLoader software ===== ===== CyBroBinLoader software =====
-  * Download latest CyBroBinLoader.exe from www.cybrotech.com+  * Download latest CyBroBinLoader.exe from https://www.cybrotech.com/software-category/tools/
   * Run CybroBinLoader.exe   * Run CybroBinLoader.exe
-  * In case Windows OS is blocking execution, click on more info and run anyway +  * In case Windows OS is blocking execution, click on "more infoand "run anyway
  
 {{ hiq_energy:hems_v1_2_0:cybrobinloader.png?nolink&0x140        }} {{ hiq_energy:hems_v1_2_0:cybrobinloader.png?nolink&0x140        }}
Line 16: Line 16:
 ===== Firmware upload ===== ===== Firmware upload =====
  
-  * Download latest HEMS firmware from:  en:hems_v1_2_0:download +  * Download latest HEMS firmware from [[en:hems_v1_2_0:download|Download]] 
-  * Select correct Cybro NAD (sticker on top of MC controller)+  * Select correct Cybro NAD (sticker on top or side of MC controller)
   * Select firmware under PLC program   * Select firmware under PLC program
   * Enable PLC program and Start PLC   * Enable PLC program and Start PLC
   * Click send   * Click send
 +  * :!: PC must be on the same network as MC controller
   * :!: Do not interrupt durring update process   * :!: Do not interrupt durring update process
 +  * :!: HEMS configuration may be lost, use BACKUP before update and later RESTORE as described under [[en:hems_v1_2_0:software#settings|Software]]
    
 {{ hiq_energy:hems_v1_2_0:cybrobinloader_selectnad.png?nolink }} {{ hiq_energy:hems_v1_2_0:cybrobinloader_selectnad.png?nolink }}
 +
 {{ hiq_energy:hems_v1_2_0:cybrobinloader_firmware.png?nolink }} {{ hiq_energy:hems_v1_2_0:cybrobinloader_firmware.png?nolink }}
  
  
 <WRAP clear></WRAP> <WRAP clear></WRAP>
- 
-===== Installation and mounting ===== 
-  * :!: Carefully open WM-1 module and configure serial communication with jumpers. (Default configuration is 9600bps, 8N1 with normal timeout) 
-  * :!: Place WM-1 module at least 10cm from other objects. Installation is not recommended inside metal cabinets. 
-  * Connect RS485 terminals to WM-1 RS485 terminals 
-    * A - A 
-    * B - B 
-    * C - GND 
-  * Connect to 230V power supply 
-  * Configure radio pairing 
- 
  
  
en/hems_v1_2_0/methods_resources/firmwareupdate.1635413853.txt.gz · Last modified: 2021/10/28 09:37 by neoxy