Line 5: Line 5:
 <WRAP column 350px> <WRAP column 350px>
  
-{{  :hiq_energy:hems:hardware:pm3-e-d_ct.png?nolink  |}}+{{  hiq_hardware:pm3-e-d_picture.png?nolink  |}}
  
 </WRAP> </WRAP>
Line 11: Line 11:
 <WRAP column 300px> <WRAP column 300px>
  
-| Model number: ^ PM3-E-D-CT                                   |+| Model number: ^ PM3-E-D                                   |
 | Connect to:   | [[en:hiq_hw:mc-230|MC-230]]           | | Connect to:   | [[en:hiq_hw:mc-230|MC-230]]           |
 | :::           | RS485 power sensor bus A - B                 | | :::           | RS485 power sensor bus A - B                 |
 | Mounting:     | DIN rail, 1M, 18 mm                          | | Mounting:     | DIN rail, 1M, 18 mm                          |
-| Dimensions:   | 65 × 72 × 94,5 mm                             | +| Dimensions:   | 66 × 72 × 100 mm                             | 
  
 ^ Used for measuring power and energy of                 || ^ Used for measuring power and energy of                 ||
Line 31: Line 31:
 ===== Features ===== ===== Features =====
  
-  * DIN rail mounting with 3x current transformers ([[en:hiq_hw:ct-3-e-xx|3-ph current transformer]]) +  * DIN rail mounting 
-  * Line voltage and THD% (total harmonic distortion) of all phases+  * Three Phase 100A Direct Fed 
 +  * Accuracy Class 0.5 (Active Energy) 
 +  * Bi-directlonal Measurement for kW and kWh 
 +  * Configurable Pulsed output (Import/ Export/Nett kWh)
   * Line Frequency   * Line Frequency
-  * Currents, Current demands and current THD% of all phases 
   * Power, maximum power demand and power factor   * Power, maximum power demand and power factor
   * Active energy imported and exported   * Active energy imported and exported
   * Reactive energy imported and exported   * Reactive energy imported and exported
 +  * Supported Modbus
 +
 +
  
 ===== General description ===== ===== General description =====
  
-The unit measures and displays the characteristics of three phase four wires(3p4w) supplies, including voltage, frequency, current, power, active and reactive energy, imported or exported. +PM3-E-D measures and displays the characteristics of 1p2w, 3p3w and 3p4w supplies, including voltage, frequency, current, power, active and reactive energy, imported or exported, harmonic etc. Bi-directional measurement makes it an ideal choice for Solar PV measurement. The units support Max. 100A direct connection, saving the cost and avoiding the trouble to connect external CTs. Two pulse outputs and 1 communication port (Modbus) are provided for remote monitoring. The unit has been approved to meet the requirements of EU Directive 2014/32/EU.
- Energy is measured in terms of kWh, kVArh. Maximum demand current can be measured over preset periods of up to 60minutes.  +
-In order to measure energy, the unit requires voltage and current inputs in addition to the supply required to power the product.  +
-The requisite current input(s) are obtained via current transformers (CT). +
-This power sensor can be configured to work with a wide range of CTs with 0.33V output, giving the unit a wide range of operation. Built-in interfaces provide pulse and RS485 Modbus RTU outputs. Configuration is password protected. +
-This power sensor can be powered from a separate auxiliary (AC or DC) supply. Alternatively, it can be powered from the monitored supply, where appropriate. +
 ===== Technical specifications ===== ===== Technical specifications =====
  
 |< 35% 40% >| |< 35% 40% >|
 ^ Technical Data                                                               || ^ Technical Data                                                               ||
-| Operating Humidity             |                                        ≤ 75% |+| Operating Humidity             |                                        ≤ 90% |
 | Storage Humidity               |                                        ≤ 95% | | Storage Humidity               |                                        ≤ 95% |
 | Operating Temperature          |                                -25°C - +50°C | | Operating Temperature          |                                -25°C - +50°C |
Line 58: Line 57:
 | Mounting                       |                         DIN rail (DIN 43880) | | Mounting                       |                         DIN rail (DIN 43880) |
 | Sealing                        |                                  IP51 Indoor | | Sealing                        |                                  IP51 Indoor |
-| Auxiliary supply voltage       |                                 Nominal ± 1% | +| Frequency                      |                                 50Hz or 60Hz |
-| Auxiliary supply frequency     |                                 Nominal ± 1% | +
-| Frequency                      |                            50Hz or 60Hz(±2%) |+
 | Power Consumption              |                                        ≤ 10W | | Power Consumption              |                                        ≤ 10W |
 ^ Accuracy                                                                     || ^ Accuracy                                                                     ||
-| Voltage, Current               |                                         0.5% | +| Voltage, Current               |                        0.2% of range maximum | 
-| Frequency                      |                        0.2% of Mid-Frequency |+| Frequency                      |                        0.1% of Mid-Frequency |
 | Power Factor                   |                           1% of Unity (0.01) | | Power Factor                   |                           1% of Unity (0.01) |
-| Active Power, Apparent Power   |                        ± 1% of Range Maximum | 
-| Reactive Power                 |                        ± 1% of Range Maximum | 
-| Reactive Energy (Varh)         |                        ± 1% of Range Maximum | 
-| Active Energy (Wh)             |                          Class 1 IEC 62053-21| 
 ^ Current transformer                                                          || ^ Current transformer                                                          ||
 | Frequency                      |                                     50-60 Hz | | Frequency                      |                                     50-60 Hz |
-| Rated current                  |                                         50 A | +| Max current                    |                                        100 A |
-| Accuracy                       |            from 20% to 120% of rated current | +
-| Phase angle                    |  less than 2 degrees at 50% of rated current | +
-| Insulation voltage             |                                      600 VAC | +
-| Maximum primary voltage        |               5000 VAC (insulated conductor) | +
-| Dielectric strength            |                              2.5 kV/1mA/1min | +
-| Operating temperature          |                                  -15 to 60°C | +
-| Operating humidity             |                                       < 85 % | +
-| Case material                  |                                   PC/UL94-V0 | +
-| Bobin                          |                                          PBT | +
-| Core                           |                                    Permalloy | +
-| Internal structure             |                                        Epoxy | +
-| Leads                          |                UL 1015, Twisted pair, 22 AWG |+
 ^ Modbus                                                                       || ^ Modbus                                                                       ||
-| Bus Type                       |                          RS485 (Semi-Duplex) |+| Transmission Mode              |                            RS485 Half-Duplex |
 | Protocol                       |                                   Modbus RTU | | Protocol                       |                                   Modbus RTU |
-| Baud Rate                      |                       1200/2400/4800/9600bps |+| Baud Rate                      |                           2400bps - 38400bps |
 | Address Range                  |                                        1-247 | | Address Range                  |                                        1-247 |
-| Max. Bus Loading               |                                        64pcs | 
-| Communication Distance         |                                  1000 Meters | 
 | Parity                         |                                EVEN/ODD/NONE | | Parity                         |                                EVEN/ODD/NONE |
 | Data Bit                       |                                            8 | | Data Bit                       |                                            8 |
-| Stop Bit                       |                                            1 |+| Stop Bit                       |                                        1 or 2|
                                                                                                  
                                                                                                  
-                                                 
-                                                 
-                                                 
-                                                 
-                                                 
-                                                 
-                                                 
-                                                 
-<WRAP pagebreak></WRAP> 
- 
-===== Dimensions ===== 
- 
-{{:hiq_energy:hems:hardware:pm3-e_ct_dimensions.png?nolink|}} 
- 
-===== Installation ===== 
- 
-{{:hiq_energy:hems:hardware:pm3-e_instalation.png?nolink|}} 
- 
-{{ :hiq_energy:hems:hardware:hiq_pm3-e-d-ct_user_manual_v1.pdf |}} {{ :hiq_energy:hems:hardware:hiq_pm3-e-d-ct_protocol_v1.6.pdf |}} 
  
 +<WRAP pagebreak></WRAP>                                                  
 +                                             
 +===== Installation & Dimensions =====
  
 +{{:hiq_hardware:sdm630-installation.png?nolink|}}
  
  
en/hiq_hw/pm3-e-d.1669798464.txt.gz · Last modified: by gdzampo