User Tools

Site Tools


en:hiq_hw:pm3-e-d

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
en:hiq_hw:pm3-e-d [2022/11/30 09:19] – [General description] gdzampoen:hiq_hw:pm3-e-d [2022/12/09 08:58] (current) saso_santelj
Line 5: Line 5:
 <WRAP column 350px> <WRAP column 350px>
  
-{{  :hiq_energy:hems:hardware:pm3-e-d_ct.png?nolink  |}}+{{  hiq_hardware:pm3-e-d_picture.png?nolink  |}}
  
 </WRAP> </WRAP>
Line 40: Line 40:
   * Active energy imported and exported   * Active energy imported and exported
   * Reactive energy imported and exported   * Reactive energy imported and exported
-  * Supported Modbus (SDM630Modbus)+  * Supported Modbus
  
  
Line 46: Line 46:
 ===== General description ===== ===== General description =====
  
-SDM630 series measures and displays the characteristics of 1p2w, 3p3w and 3p4w supplies, including voltage, frequency, current, power, active and reactive energy, imported or exported, harmonic etc. Bi-directional measurement makes it an ideal choice for Solar PV measurement. The units support Max. 100A direct connection, saving the cost and avoiding the trouble to connect external CTs. Two pulse outputs and 1 communication port (Mbus/Modbus) are provided for remote monitoring. The unit has been approved to meet the requirements of EU Directive 2014/32/EU.+PM3-E-D measures and displays the characteristics of 1p2w, 3p3w and 3p4w supplies, including voltage, frequency, current, power, active and reactive energy, imported or exported, harmonic etc. Bi-directional measurement makes it an ideal choice for Solar PV measurement. The units support Max. 100A direct connection, saving the cost and avoiding the trouble to connect external CTs. Two pulse outputs and 1 communication port (Modbus) are provided for remote monitoring. The unit has been approved to meet the requirements of EU Directive 2014/32/EU.
 ===== Technical specifications ===== ===== Technical specifications =====
  
 |< 35% 40% >| |< 35% 40% >|
 ^ Technical Data                                                               || ^ Technical Data                                                               ||
-| Operating Humidity                                                    ≤ 75% |+| Operating Humidity                                                    ≤ 90% |
 | Storage Humidity                                                      ≤ 95% | | Storage Humidity                                                      ≤ 95% |
 | Operating Temperature          |                                -25°C - +50°C | | Operating Temperature          |                                -25°C - +50°C |
Line 57: Line 57:
 | Mounting                                               DIN rail (DIN 43880) | | Mounting                                               DIN rail (DIN 43880) |
 | Sealing                        |                                  IP51 Indoor | | Sealing                        |                                  IP51 Indoor |
-| Auxiliary supply voltage                                       Nominal ± 1% | +| Frequency                      |                                 50Hz or 60Hz |
-| Auxiliary supply frequency                                     Nominal ± 1% | +
-| Frequency                      |                            50Hz or 60Hz(±2%) |+
 | Power Consumption              |                                        ≤ 10W | | Power Consumption              |                                        ≤ 10W |
 ^ Accuracy                                                                     || ^ Accuracy                                                                     ||
-| Voltage, Current                                                       0.5% | +| Voltage, Current                                      0.2of range maximum 
-| Frequency                      |                        0.2% of Mid-Frequency |+| Frequency                      |                        0.1% of Mid-Frequency |
 | Power Factor                                             1% of Unity (0.01) | | Power Factor                                             1% of Unity (0.01) |
-| Active Power, Apparent Power                          ± 1% of Range Maximum | 
-| Reactive Power                                        ± 1% of Range Maximum | 
-| Reactive Energy (Varh)                                ± 1% of Range Maximum | 
-| Active Energy (Wh)                                      Class 1 IEC 62053-21| 
 ^ Current transformer                                                          || ^ Current transformer                                                          ||
 | Frequency                      |                                     50-60 Hz | | Frequency                      |                                     50-60 Hz |
-Rated current                                                          50 A | +Max current                    |                                        100 A |
-| Accuracy                                  from 20% to 120% of rated current | +
-| Phase angle                    |  less than 2 degrees at 50% of rated current | +
-| Insulation voltage                                                  600 VAC | +
-| Maximum primary voltage        |               5000 VAC (insulated conductor) | +
-| Dielectric strength            |                              2.5 kV/1mA/1min | +
-| Operating temperature          |                                  -15 to 60°C | +
-| Operating humidity                                                   < 85 % | +
-| Case material                  |                                   PC/UL94-V0 | +
-| Bobin                          |                                          PBT | +
-| Core                                                              Permalloy | +
-| Internal structure             |                                        Epoxy | +
-| Leads                          |                UL 1015, Twisted pair, 22 AWG |+
 ^ Modbus                                                                       || ^ Modbus                                                                       ||
-Bus Type                                                RS485 (Semi-Duplex|+Transmission Mode                                         RS485 Half-Duplex |
 | Protocol                                                         Modbus RTU | | Protocol                                                         Modbus RTU |
-| Baud Rate                      |                       1200/2400/4800/9600bps |+| Baud Rate                      |                           2400bps - 38400bps |
 | Address Range                  |                                        1-247 | | Address Range                  |                                        1-247 |
-| Max. Bus Loading                                                      64pcs | 
-| Communication Distance                                          1000 Meters | 
 | Parity                                                        EVEN/ODD/NONE | | Parity                                                        EVEN/ODD/NONE |
 | Data Bit                                                                  8 | | Data Bit                                                                  8 |
-| Stop Bit                                                                  1 |+| Stop Bit                                                              or 2|
                                                                                                  
                                                                                                  
-                                                 
-                                                 
-                                                 
-                                                 
-                                                 
-                                                 
-                                                 
-                                                 
-<WRAP pagebreak></WRAP> 
- 
-===== Dimensions ===== 
- 
-{{:hiq_energy:hems:hardware:pm3-e_ct_dimensions.png?nolink|}} 
- 
-===== Installation ===== 
- 
-{{:hiq_energy:hems:hardware:pm3-e_instalation.png?nolink|}} 
- 
-{{ :hiq_energy:hems:hardware:hiq_pm3-e-d-ct_user_manual_v1.pdf |}} {{ :hiq_energy:hems:hardware:hiq_pm3-e-d-ct_protocol_v1.6.pdf |}} 
  
 +<WRAP pagebreak></WRAP>                                                  
 +                                             
 +===== Installation & Dimensions =====
  
 +{{:hiq_hardware:sdm630-installation.png?nolink|}}
  
  
en/hiq_hw/pm3-e-d.1669799944.txt.gz · Last modified: 2022/11/30 09:19 by gdzampo