en:hiq_hw:pm3-e-d [2022/11/30 09:19] – [General description] gdzampoen:hiq_hw:pm3-e-d [2022/12/09 08:58] (current) – saso_santelj
Line 5: Line 5:
 <WRAP column 350px> <WRAP column 350px>
  
-{{  :hiq_energy:hems:hardware:pm3-e-d_ct.png?nolink  |}}+{{  hiq_hardware:pm3-e-d_picture.png?nolink  |}}
  
 </WRAP> </WRAP>
Line 40: Line 40:
   * Active energy imported and exported   * Active energy imported and exported
   * Reactive energy imported and exported   * Reactive energy imported and exported
-  * Supported Modbus (SDM630Modbus)+  * Supported Modbus
  
  
Line 46: Line 46:
 ===== General description ===== ===== General description =====
  
-SDM630 series measures and displays the characteristics of 1p2w, 3p3w and 3p4w supplies, including voltage, frequency, current, power, active and reactive energy, imported or exported, harmonic etc. Bi-directional measurement makes it an ideal choice for Solar PV measurement. The units support Max. 100A direct connection, saving the cost and avoiding the trouble to connect external CTs. Two pulse outputs and 1 communication port (Mbus/Modbus) are provided for remote monitoring. The unit has been approved to meet the requirements of EU Directive 2014/32/EU.+PM3-E-D measures and displays the characteristics of 1p2w, 3p3w and 3p4w supplies, including voltage, frequency, current, power, active and reactive energy, imported or exported, harmonic etc. Bi-directional measurement makes it an ideal choice for Solar PV measurement. The units support Max. 100A direct connection, saving the cost and avoiding the trouble to connect external CTs. Two pulse outputs and 1 communication port (Modbus) are provided for remote monitoring. The unit has been approved to meet the requirements of EU Directive 2014/32/EU.
 ===== Technical specifications ===== ===== Technical specifications =====
  
 |< 35% 40% >| |< 35% 40% >|
 ^ Technical Data                                                               || ^ Technical Data                                                               ||
-| Operating Humidity             |                                        ≤ 75% |+| Operating Humidity             |                                        ≤ 90% |
 | Storage Humidity               |                                        ≤ 95% | | Storage Humidity               |                                        ≤ 95% |
 | Operating Temperature          |                                -25°C - +50°C | | Operating Temperature          |                                -25°C - +50°C |
Line 57: Line 57:
 | Mounting                       |                         DIN rail (DIN 43880) | | Mounting                       |                         DIN rail (DIN 43880) |
 | Sealing                        |                                  IP51 Indoor | | Sealing                        |                                  IP51 Indoor |
-| Auxiliary supply voltage       |                                 Nominal ± 1% | +| Frequency                      |                                 50Hz or 60Hz |
-| Auxiliary supply frequency     |                                 Nominal ± 1% | +
-| Frequency                      |                            50Hz or 60Hz(±2%) |+
 | Power Consumption              |                                        ≤ 10W | | Power Consumption              |                                        ≤ 10W |
 ^ Accuracy                                                                     || ^ Accuracy                                                                     ||
-| Voltage, Current               |                                         0.5% | +| Voltage, Current               |                        0.2% of range maximum | 
-| Frequency                      |                        0.2% of Mid-Frequency |+| Frequency                      |                        0.1% of Mid-Frequency |
 | Power Factor                   |                           1% of Unity (0.01) | | Power Factor                   |                           1% of Unity (0.01) |
-| Active Power, Apparent Power   |                        ± 1% of Range Maximum | 
-| Reactive Power                 |                        ± 1% of Range Maximum | 
-| Reactive Energy (Varh)         |                        ± 1% of Range Maximum | 
-| Active Energy (Wh)             |                          Class 1 IEC 62053-21| 
 ^ Current transformer                                                          || ^ Current transformer                                                          ||
 | Frequency                      |                                     50-60 Hz | | Frequency                      |                                     50-60 Hz |
-| Rated current                  |                                         50 A | +| Max current                    |                                        100 A |
-| Accuracy                       |            from 20% to 120% of rated current | +
-| Phase angle                    |  less than 2 degrees at 50% of rated current | +
-| Insulation voltage             |                                      600 VAC | +
-| Maximum primary voltage        |               5000 VAC (insulated conductor) | +
-| Dielectric strength            |                              2.5 kV/1mA/1min | +
-| Operating temperature          |                                  -15 to 60°C | +
-| Operating humidity             |                                       < 85 % | +
-| Case material                  |                                   PC/UL94-V0 | +
-| Bobin                          |                                          PBT | +
-| Core                           |                                    Permalloy | +
-| Internal structure             |                                        Epoxy | +
-| Leads                          |                UL 1015, Twisted pair, 22 AWG |+
 ^ Modbus                                                                       || ^ Modbus                                                                       ||
-| Bus Type                       |                          RS485 (Semi-Duplex) |+| Transmission Mode              |                            RS485 Half-Duplex |
 | Protocol                       |                                   Modbus RTU | | Protocol                       |                                   Modbus RTU |
-| Baud Rate                      |                       1200/2400/4800/9600bps |+| Baud Rate                      |                           2400bps - 38400bps |
 | Address Range                  |                                        1-247 | | Address Range                  |                                        1-247 |
-| Max. Bus Loading               |                                        64pcs | 
-| Communication Distance         |                                  1000 Meters | 
 | Parity                         |                                EVEN/ODD/NONE | | Parity                         |                                EVEN/ODD/NONE |
 | Data Bit                       |                                            8 | | Data Bit                       |                                            8 |
-| Stop Bit                       |                                            1 |+| Stop Bit                       |                                        1 or 2|
                                                                                                  
                                                                                                  
-                                                 
-                                                 
-                                                 
-                                                 
-                                                 
-                                                 
-                                                 
-                                                 
-<WRAP pagebreak></WRAP> 
- 
-===== Dimensions ===== 
- 
-{{:hiq_energy:hems:hardware:pm3-e_ct_dimensions.png?nolink|}} 
- 
-===== Installation ===== 
- 
-{{:hiq_energy:hems:hardware:pm3-e_instalation.png?nolink|}} 
- 
-{{ :hiq_energy:hems:hardware:hiq_pm3-e-d-ct_user_manual_v1.pdf |}} {{ :hiq_energy:hems:hardware:hiq_pm3-e-d-ct_protocol_v1.6.pdf |}} 
  
 +<WRAP pagebreak></WRAP>                                                  
 +                                             
 +===== Installation & Dimensions =====
  
 +{{:hiq_hardware:sdm630-installation.png?nolink|}}
  
  
en/hiq_hw/pm3-e-d.1669799944.txt.gz · Last modified: by gdzampo