User Tools

Site Tools


en:hotel:hardware:hr-2-iq

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
en:hotel:hardware:hr-2-iq [2018/11/22 08:04] – ↷ Page moved from en:bms:hotel:hardware:hr-2-iq to en:hotel:hardware:hr-2-iq goran.kocjancicen:hotel:hardware:hr-2-iq [2018/11/22 09:25] (current) – removed goran.kocjancic
Line 1: Line 1:
-====== Hotel room controller ====== 
- 
-**Hotel room master controller** 
- 
-<WRAP column 350px> 
- 
-{{  hiq_building_automation:hiq_hotel:hw:hr-2.png?nolink  }} 
- 
-</WRAP> 
- 
-<WRAP column 300px> 
- 
-| Model number: ^   HR-2              | 
-| Mounting:     | DIN rail, 6M, 106mm | 
-| Dimensions:   | 106x108x58mm        | 
- 
-===== Applications ===== 
- 
-  * Hotel room automation 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
-===== Features ===== 
- 
-  * Welcome light 
-  * Power relay 
-  * HVAC control 
-  * Room SOS 
- 
-===== General description ===== 
- 
-**Hotel room controller** controls all basic hotel room devices: welcome light, power relay, HVAC, card holder and SOS pull-switch. By itself is sufficient for basic hotel room automation. It is easy configurable and can be upgraded with many additional expansion units so it ensures practically any level of hotel room automation. 
- 
-Easy commissioning with auto-addressing, easy configuration and advanced diagnostic ensures cost effective and quick system set-up and easy maintenance during whole life cycle.  
-===== Technical specification ===== 
- 
-| Relay outputs:                              3A/250V | 
-| Lock output:                            500mA/12VDC | 
-| Transistor outputs:    |                  250mA/24VDC | 
-| Communication:                   RS485, 2 × IEX bus | 
-| Power supply:          |                         240V | 
-| Ingress protection:    |                         IP20 | 
-| Operating temperature: |                      0..45°C | 
-| Storage temperature:                      -20..75°C | 
-| Relative humidity:                       0..95% n/c | 
- 
-===== Terminals ===== 
- 
-| Power supply 240 V AC          ^  L      ^     | Power supply input     | Digital inputs common    19    GND   | Common                                  | 
-| :::                            ^  N      ^     | :::                  |:::| Digital inputs          ^  20    IX0   | Card holder                             | 
-| Room power relay                PWR    ^     | Relay outputs        |:::| :::                      21    IX1   | Thermostat                              | 
-| Fan-coil 1st speed              F1         | :::                  |:::| :::                      22    IX2   | Main door reed relay                    | 
-| Fan-coil 2nd speed              F2         | :::                  |:::| :::                      23    IX3   | Welcome light push-button               | 
-| Fan-coil 3rd speed              F3         | :::                  |:::| :::                      24    IX4   | SOS pull-switch                         | 
-| Fan-coil valve                  VA         | :::                  |:::| :::                      25    IX5   | Info panel control push-button          | 
-| Welcome light                  ^  QX0    ^     | :::                  |:::| :::                      26    IX6   | Window switch                           | 
-| Thermostat ECO mode            ^  QX1    ^     | :::                  |:::| :::                      27    IX7                                           | 
-|                                                                      ||||:::                                                                                |||| 
-| Internal IEX bus GND            GND    ^  10   | Internal IEX bus     |:::| +12 VDC source          ^  28    +12V  | Access control +12V                     | 
-| Internal IEX bus CANL          ^  ICANL  ^  11   | :::                  |:::| RS485                    29    A     | Access control RXD-A                    | 
-| Internal IEX bus CANH          ^  ICANH  ^  12   | :::                  |:::| :::                      30    B     | Access control TXD-B                    | 
-| Internal IEX bus +24V          ^  +24V    13   | :::                  |:::| GND                      31    GND   | Access control GND                      | 
-| External IEX bus GND            GND    ^  14   | External IEX bus     |:::| GND                      32    GND   | LOCK and Qx2-4 common                   | 
-| External IEX bus CANL          ^  ECANL  ^  15   | :::                  |:::| Lock output              33    LOCK  | Door lock                               | 
-| External IEX bus CANH          ^  ECANH  ^  16   | :::                  |:::| Transistor outputs      ^  34    QX2   | Info panel - Make My Room               | 
-| External IEX bus in +24V        +IN    ^  17   | :::                  |:::| :::                      35    QX3   | Info panel - Do Not Disturb             | 
-| External IEX bus out +24V      ^  +OUT    18   | :::                  |:::| :::                      36    QX4   | Info panel - Room Service Request       | 
- 
- 
- 
  
en/hotel/hardware/hr-2-iq.1542873841.txt.gz · Last modified: 2018/11/22 08:04 by goran.kocjancic