- | ====== Hotel room controller ====== | ||
- | |||
- | **Hotel room master controller** | ||
- | |||
- | <WRAP column 350px> | ||
- | |||
- | {{ hiq_building_automation: | ||
- | |||
- | </ | ||
- | |||
- | <WRAP column 300px> | ||
- | |||
- | | Model number: ^ | ||
- | | Mounting: | ||
- | | Dimensions: | ||
- | |||
- | ===== Applications ===== | ||
- | |||
- | * Hotel room automation | ||
- | |||
- | </ | ||
- | |||
- | <WRAP clear></ | ||
- | |||
- | ===== Features ===== | ||
- | |||
- | * Welcome light | ||
- | * Power relay | ||
- | * HVAC control | ||
- | * Room SOS | ||
- | |||
- | ===== General description ===== | ||
- | |||
- | **Hotel room controller** controls all basic hotel room devices: welcome light, power relay, HVAC, card holder and SOS pull-switch. By itself is sufficient for basic hotel room automation. It is easy configurable and can be upgraded with many additional expansion units so it ensures practically any level of hotel room automation. | ||
- | |||
- | Easy commissioning with auto-addressing, | ||
- | ===== Technical specification ===== | ||
- | |||
- | | Relay outputs: | ||
- | | Lock output: | ||
- | | Transistor outputs: | ||
- | | Communication: | ||
- | | Power supply: | ||
- | | Ingress protection: | ||
- | | Operating temperature: | ||
- | | Storage temperature: | ||
- | | Relative humidity: | ||
- | |||
- | ===== Terminals ===== | ||
- | |||
- | | Power supply 240 V AC ^ L ^ | ||
- | | ::: ^ N ^ | ||
- | | Room power relay | ||
- | | Fan-coil 1st speed | ||
- | | Fan-coil 2nd speed | ||
- | | Fan-coil 3rd speed | ||
- | | Fan-coil valve | ||
- | | Welcome light ^ QX0 ^ | ||
- | | Thermostat ECO mode ^ QX1 ^ | ||
- | | ||||::: | ||
- | | Internal IEX bus GND | ||
- | | Internal IEX bus CANL ^ ICANL ^ 11 | ::: |:::| RS485 | ||
- | | Internal IEX bus CANH ^ ICANH ^ 12 | ::: |:::| ::: | ||
- | | Internal IEX bus +24V ^ +24V | ||
- | | External IEX bus GND | ||
- | | External IEX bus CANL ^ ECANL ^ 15 | ::: |:::| Lock output | ||
- | | External IEX bus CANH ^ ECANH ^ 16 | ::: |:::| Transistor outputs | ||
- | | External IEX bus in +24V | ||
- | | External IEX bus out +24V ^ +OUT | ||
- | |||
- | |||
- | |||