en:hotel:hardware:hr-ext-iq
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revision | |||
| en:hotel:hardware:hr-ext-iq [2018/11/22 08:04] – ↷ Page moved from en:bms:hotel:hardware:hr-ext-iq to en:hotel:hardware:hr-ext-iq goran.kocjancic | en:hotel:hardware:hr-ext-iq [2018/11/22 09:25] (current) – removed goran.kocjancic | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | ====== Hotel room extension ====== | ||
| - | |||
| - | **Hotel room lights and blinds controller ** | ||
| - | |||
| - | <WRAP column 350px> | ||
| - | |||
| - | {{ hiq_building_automation: | ||
| - | |||
| - | </ | ||
| - | |||
| - | <WRAP column 300px> | ||
| - | |||
| - | | Model number: ^ | ||
| - | | Mounting: | ||
| - | | Dimensions: | ||
| - | |||
| - | ===== Applications ===== | ||
| - | |||
| - | * Hotel room lights controller | ||
| - | * Hotel room blinds controller | ||
| - | * Hotel room bathroom fan controller | ||
| - | |||
| - | </ | ||
| - | |||
| - | <WRAP clear></ | ||
| - | |||
| - | ===== Features ===== | ||
| - | |||
| - | * Configurable welcome and goodby scene | ||
| - | * Advanced master light control (night mode) | ||
| - | * Easy push-button control | ||
| - | * Periodic / controlled bathroom ventilation when room is inactive, occupied or free | ||
| - | |||
| - | ===== General description ===== | ||
| - | |||
| - | **Hotel room extension** if expansion for Hotel room controller which allows to completely control all hotel room lights, bathroom fan and blinds. | ||
| - | |||
| - | ===== Technical specification ===== | ||
| - | |||
| - | | Output power per relay | | | ||
| - | | - incandescent / halogen 230V | ||
| - | | - halogen 12 V with transformer | ||
| - | | - fluorescent with electronic ballast | 400 W| | ||
| - | | - parallel compensated fluo lamps | ||
| - | | Total output power (all relays): | ||
| - | | Inputs | ||
| - | | Maximum input cable length: | ||
| - | | Power supply: | ||
| - | | Ingress protection: | ||
| - | | Operating temperature: | ||
| - | | Storage temperature: | ||
| - | | Relative humidity: | ||
| - | |||
| - | ===== Terminals ===== | ||
| - | |||
| - | | Lights power supply ^ L ^ | ||
| - | | ::: | ||
| - | | | ||
| - | | Light 0 live ^ QX0 ^ | ||
| - | | | ||
| - | | Light 1 live ^ QX1 ^ | ||
| - | | Light 2 live ^ QX2 ^ | ||
| - | | | ||
| - | | Light 3 live ^ QX3 ^ | ||
| - | | | ||
| - | | Light 4 live ^ QX4 ^ 10 | Relay output 4 |:::| Digital input 4 ^ 28 ^ IX4 | Light 4 push-button | ||
| - | | | ||
| - | | Light 5 live ^ QX5 ^ 12 | Relay output 5 |:::| Digital input 5 ^ 30 ^ IX5 | Light 5 push-button | ||
| - | | Light 6 live ^ QX6 ^ 13 | Relay output 6 |:::| Digital input 6 ^ 31 ^ IX6 | Light 6 push-button | ||
| - | | | ||
| - | | Bath fan ^ QX7 ^ 15 | Relay output 7 |:::| Digital input 7 ^ 33 ^ IX7 | Bath fan push-button | ||
| - | | Blinds 0 up ^ QX8 ^ 16 | Relay output 8 |:::| Digital input 8 ^ 34 ^ IX8 | Blinds 0 up push-button | ||
| - | | | ||
| - | | Blinds 0 down ^ QX9 ^ 18 | Relay output 9 |:::| Digital input 9 ^ 36 ^ IX9 | Blinds 0 down push-button | ||
| - | |||
| - | |||
en/hotel/hardware/hr-ext-iq.1542873841.txt.gz · Last modified: by goran.kocjancic
