 ===== General description ===== ===== General description =====
  
-The discrete light controller LC-8-IQ is HIQ intelligent expansion module primarily used for controlling discrete (non-dimmable) lights. Featuring high power relay output, it can control other consumers too (mains sockets, heaters, fans,..). LC-10-IQ can be used as stand-alone or part of the integrated system, when connected to one of HIQ Home Controller. Many features are available in the stand alone mode, while advanced features like scenes, scheduling, smartphone operation, internet connection are only available when connected to the appropriate Home Controller.+The discrete light controller LC-8-IQ is HIQ intelligent expansion module primarily used for controlling discrete (non-dimmable) lights. Featuring high power relay output, it can control other consumers too (mains sockets, heaters, fans,..). Module can be used as stand-alone or part of the integrated system, when connected to one of HIQ Home Controller. Many features are available in the stand alone mode, while advanced features like scenes, scheduling, smartphone operation, internet connection are only available when connected to the appropriate Home Controller.
  
 ===== Technical specification ===== ===== Technical specification =====
Line 60: Line 60:
 | Total output power (all relays):      |                        4000 W| | Total output power (all relays):      |                        4000 W|
 | Nominal output current:                                        10 A| | Nominal output current:                                        10 A|
-| Nominal current for parallel outputs: |                          10 A|+| Nominal current for parallel outputs: |                          20 A|
 | Inputs                                |  internal pull-up, 12 V, 2 mA| | Inputs                                |  internal pull-up, 12 V, 2 mA|
 | Maximum input cable length:                                    50 m| | Maximum input cable length:                                    50 m|
Line 71: Line 71:
 ===== Terminals ===== ===== Terminals =====
  
-| Lights power supply ^  L  ^     | Relay outputs common |   | Power supply          19   ^ 24V | +24 VDC power supply +{{:en:ms_main:lc-8-iq_terminals.png?500|}}
-:::                 ^  L  ^     | :::                  |:::| :::                  ^  20    0V | 0 VDC power supply    | +
-|                                                  |:::|                      ^  21                             | +
-| Light 0 live        ^ QX0 ^     | Relay output 0       |:::| Digital input 0      ^  22   ^ IX0 | Light 0 push-button   | +
-|                                                  |:::|                      ^  23                             | +
-| Light 1 live        ^ QX1 ^     | Relay output 1       |:::| Digital input 1      ^  24   ^ IX1 | Light 1 push-button   | +
-| Light 2 live        ^ QX2 ^     | Relay output 2       |:::| Digital input 2      ^  25   ^ IX2 | Light 2 push-button   | +
-|                             |                      |:::|                      ^  26                             | +
-| Light 3 live        ^ QX3 ^     | Relay output 3       |:::| Digital input 3      ^  27   ^ IX3 | Light 3 push-button   | +
-|                                                       ||||:::                                   |                     ||| +
-| Light 4 live        ^ QX4 ^  10   | Relay output 4       |:::| Digital input 4      ^  28   ^ IX4 | Light 4 push-button   | +
-|                          11                        |:::|                      ^  29                             | +
-| Light 5 live        ^ QX5 ^  12   | Relay output 5       |:::| Digital input 5      ^  30   ^ IX5 | Light 5 push-button   | +
-| Light 6 live        ^ QX6 ^  13   | Relay output 6       |:::| Digital input 6      ^  31   ^ IX6 | Light 6 push-button   | +
-|                          14                        |:::|                      ^  32                             | +
-| Light 7 live        ^ QX7 ^  15   | Relay output 7       |:::| Digital input 7      ^  33   ^ IX7 | Light 7 push-button   | +
-| Light 8 live        ^ QX8 ^  16   | Relay output 8       |:::| Digital input 8      ^  34   ^ IX8 | Light 8 push-button   | +
-|                          17                        |:::|                      ^  35                             | +
-| Light 9 live        ^ QX9 ^  18   | Relay output 9       |:::| Digital input 9      ^  36   ^ IX9 | Light 9 push-button   |+
  
-{{  hiq_hardware:lc-10-iq-in.png?direct 1000 }} 
  
-{{  hiq_hardware:lc-10-iq-out.png?direct 1000 }}+===== Modes ===== 
 + 
 +{{:en:ms_main:lc-8-iq_input_mode.png?400|}} 
 + 
 +{{:en:ms_main:lc-8-iq_output_mode.png?400|}} 
 + 