| 2. connecting PV inverter by Modbus TCP to EVSE (only for SolarEdge inverters) | 2. connecting PV inverter by Modbus TCP to EVSE (only for SolarEdge inverters) | ||
| - | === SolarEdge | + | === EVSE and PV inverter |
| |< 700px >| | |< 700px >| | ||
| - | ^ EVSE and PV inverter connection | | ||
| | {{ : | | {{ : | ||
| + | |||
| + | To add inverter on HEMS configurator: | ||
| + | * on settings page inside source table, select SolarEdge inverter. Please see [[en: | ||
| + | * on io mux page set IP address for inverter. Please see [[en: | ||
| To setup Modbus TCP on Inverter using SetApp: | To setup Modbus TCP on Inverter using SetApp: | ||
| * | * | ||
| * RS485-1 -> Protocol -> SunSpec (Non-SE Logger) | * RS485-1 -> Protocol -> SunSpec (Non-SE Logger) | ||
| - | * RS485-1 -> Device ID, and enter the number 1. | + | * RS485-1 -> Device ID, and enter the number 1 |
| - | | + | * Modbus TCP and set to Enable |
| - | | + | |
| - | * | + | |
| - | *TCP port is 1502 by default. | + | **Note**:\\ The TCP server idle time is 2 minutes. In order to leave the connection open, the request should be made within 2 minutes.\\ It is important to follow rules above, firstly to set HEMS configurator following Inverter setup due to 2 minutes time frame. |