====== Configurator ====== ===== Overview ===== |< 475px 50px >| ^ 1 ^ Page navigation | | Overview page || | Access code management page || | Settings page || | UI settings page || | Events overview page || ^ 2 ^ Entry procedure steps status | | [[en:sg3:configurator:count_status|]] || | [[en:sg3:configurator:disinfect_status|]] || | [[en:sg3:configurator:temperature_status|]] || | [[en:sg3:configurator:code_status|]] || | [[en:sg3:configurator:confirmation_status|]] || | [[en:sg3:configurator:entry_status|]] || ^ 3 ^ [[en:sg3:configurator:schematics|]] | ^ 4 ^ Occupation counts | | Occupation count, click to correct the actual number of visitors. || | Occupation limits L1 / L2 || ^ 5 ^ Command buttons | | Gates Auto / Manual mode toggle || | Alarm reset button || | Confirmation button || {{:en:sg3:configurator_1.png?direct&600|}} ===== Access Code management ===== |< 475px 50px >| ^ 1 ^ Edited code | | Click to enter the code you want to edit. || ^ 2 ^ Code type | | Click to select edited code type. Options ate L1 (level 1), L2 (level 2) or UL (unlimited). || ^ 3 ^ Access point limits | | Click to enter count limits for each access point. || | If SG3 is the only access point in the local network, enter only in position 00 (upper left field). Enter the allowed number of entries or 255 for unlimited. || ^ 4 ^ Code activation date | | Set code activation date and time. Set all to 0 for the code that is active immediately. || ^ 8 ^ Code expiration date | | Set code expiration date and time. Set all to 0 for a code that has no validity limit. || ^ 6 ^ Edit code commands | | ''[ search ]'' = Find settings for "edit code". || | ''[ save ]'' = Saves the code being edited with all settings. || | ''[ clear ]'' = Clear all edit settings. || | ''[ delete ]'' = Delete edit code from the list. || ^ 7 ^ Codes list | | List of access codes on the controller. Clicking on the code picks up all the code values in the edit fields above. || {{:en:sg3:configurator_2.png?direct&600|}} ===== Settings ===== |< 475px 50px >| ^ 1 ^ Entry conditions | | Count limits: set count limits for L1 and L2; 0=not limited || | Disinfection: select if hand disinfection is required || | Thermal scan: select if body temperature scan is required s || | Reader: select if code reader is required || | Confirmation: select if confirmation is required || ^ 2 ^ Entry detection settings | | Entry detection type: select entry detection type || | Entry time-out: max time between consecutive steps || | Confirmation time-out: max time allowed for confirmation || | Block time-out: time for hi temperature or wrong code alert || | After all time-outs entry procedure restarts. || ^ 3 ^ Code reader settings | | Access point ID: ID for built in access point. Used when S Gate is part of bigger Access control system, if not, leave 0. || | Thermal scan timeout: set the time for which the system remembers the temperature scan for the code user || | Access master code: set the code for local codes management || | Send LAN code query: set to enable sending code queries to other access controllers on LAN || | Process LAN code query: set to process queries from other controllers on LAN || ^ 4 ^ Auxiliary input settings | | AUX input type: set auxiliary input function to presence sensor or to call button || | Presence / Call time-out: aux function timeout || ^ 5 ^ Gates settings | | Entry gate time-out: set entry gate signal timeout, 0=no entry gate || | Exit gate time-out: set exit gate signal timeout, 0=no exit gate || ^ 6 ^ Alarm settings | | Alarm duration: alarm active duration time || | Alarm beeper enabled: set to enable continuous beep during alarm || | Reset alarm on exit: set to reset alarm when exit is detected || ^ 7 ^ Hardware overview | | Control system overview || | Select ''[ Autodetect ]'' to find S Gate controller in LAN (when red Xes are displayed) || ^ 8 ^ Wireless devices management | | []wireless management: set to enable management of wireless devices || | first icon: wireless device paired status (x=none, ✔=paired) || | second icon: displaying wireless signal strength || | third icon: wireless device operating as repeater (click to enable). || | ''[-]'': delete wireless device || | ''[+]'': add wireless device || ^ 9 ^ Controller date and time settings | | set S Gate controller date and time. || ^ 10 ^ Parameters management | | ''[init parameters ]'': initialize all parameters to factory default values || | ''[save parameters ]'': save all parameters to permanent memory || | ''[read parameters ]'': read all parameters from permanent memory || {{:en:sg3:configurator_3.png?direct&600|}} ===== User interfaces settings ===== |< 475px 50px >| ^ 1 ^ LED display texts settings | | Click to set the texts displayed on the LED display. Edit text alignment with spaces. || ^ 2 ^ GUI display texts settings | | Click to set the texts that appear on the graphical user interface. The text will be centered automatically. || {{:en:sg3:configurator_4.png?direct&600|}} ===== Events overview ===== |< 475px 50px >| ^ 1 ^ Events list | | The last 20 event codes and data are displayed. Event #00 happened last. || ^ 2 ^ Events legend | | Legend for event code and data. || {{:en:sg3:configurator_5.png?direct&600|}}