====== Configurator ======
===== Overview =====
|< 475px 50px >|
^ 1 ^ Page navigation |
| Overview page ||
| Access code management page ||
| Settings page ||
| UI settings page ||
| Events overview page ||
^ 2 ^ Entry procedure steps status |
| [[en:sg3:configurator:count_status|]] ||
| [[en:sg3:configurator:disinfect_status|]] ||
| [[en:sg3:configurator:temperature_status|]] ||
| [[en:sg3:configurator:code_status|]] ||
| [[en:sg3:configurator:confirmation_status|]] ||
| [[en:sg3:configurator:entry_status|]] ||
^ 3 ^ [[en:sg3:configurator:schematics|]] |
^ 4 ^ Occupation counts |
| Occupation count, click to correct the actual number of visitors. ||
| Occupation limits L1 / L2 ||
^ 5 ^ Command buttons |
| Gates Auto / Manual mode toggle ||
| Alarm reset button ||
| Confirmation button ||
{{:en:sg3:configurator_1.png?direct&600|}}
===== Access Code management =====
|< 475px 50px >|
^ 1 ^ Edited code |
| Click to enter the code you want to edit. ||
^ 2 ^ Code type |
| Click to select edited code type. Options ate L1 (level 1), L2 (level 2) or UL (unlimited). ||
^ 3 ^ Access point limits |
| Click to enter count limits for each access point. ||
| If SG3 is the only access point in the local network, enter only in position 00 (upper left field). Enter the allowed number of entries or 255 for unlimited. ||
^ 4 ^ Code activation date |
| Set code activation date and time. Set all to 0 for the code that is active immediately. ||
^ 8 ^ Code expiration date |
| Set code expiration date and time. Set all to 0 for a code that has no validity limit. ||
^ 6 ^ Edit code commands |
| ''[ search ]'' = Find settings for "edit code". ||
| ''[ save ]'' = Saves the code being edited with all settings. ||
| ''[ clear ]'' = Clear all edit settings. ||
| ''[ delete ]'' = Delete edit code from the list. ||
^ 7 ^ Codes list |
| List of access codes on the controller. Clicking on the code picks up all the code values in the edit fields above. ||
{{:en:sg3:configurator_2.png?direct&600|}}
===== Settings =====
|< 475px 50px >|
^ 1 ^ Entry conditions |
| Count limits: set count limits for L1 and L2; 0=not limited ||
| Disinfection: select if hand disinfection is required ||
| Thermal scan: select if body temperature scan is required s ||
| Reader: select if code reader is required ||
| Confirmation: select if confirmation is required ||
^ 2 ^ Entry detection settings |
| Entry detection type: select entry detection type ||
| Entry time-out: max time between consecutive steps ||
| Confirmation time-out: max time allowed for confirmation ||
| Block time-out: time for hi temperature or wrong code alert ||
| After all time-outs entry procedure restarts. ||
^ 3 ^ Code reader settings |
| Access point ID: ID for built in access point. Used when S Gate is part of bigger Access control system, if not, leave 0. ||
| Thermal scan timeout: set the time for which the system remembers the temperature scan for the code user ||
| Access master code: set the code for local codes management ||
| Send LAN code query: set to enable sending code queries to other access controllers on LAN ||
| Process LAN code query: set to process queries from other controllers on LAN ||
^ 4 ^ Auxiliary input settings |
| AUX input type: set auxiliary input function to presence sensor or to call button ||
| Presence / Call time-out: aux function timeout ||
^ 5 ^ Gates settings |
| Entry gate time-out: set entry gate signal timeout, 0=no entry gate ||
| Exit gate time-out: set exit gate signal timeout, 0=no exit gate ||
^ 6 ^ Alarm settings |
| Alarm duration: alarm active duration time ||
| Alarm beeper enabled: set to enable continuous beep during alarm ||
| Reset alarm on exit: set to reset alarm when exit is detected ||
^ 7 ^ Hardware overview |
| Control system overview ||
| Select ''[ Autodetect ]'' to find S Gate controller in LAN (when red Xes are displayed) ||
^ 8 ^ Wireless devices management |
| []wireless management: set to enable management of wireless devices ||
| first icon: wireless device paired status (x=none, ✔=paired) ||
| second icon: displaying wireless signal strength ||
| third icon: wireless device operating as repeater (click to enable). ||
| ''[-]'': delete wireless device ||
| ''[+]'': add wireless device ||
^ 9 ^ Controller date and time settings |
| set S Gate controller date and time. ||
^ 10 ^ Parameters management |
| ''[init parameters ]'': initialize all parameters to factory default values ||
| ''[save parameters ]'': save all parameters to permanent memory ||
| ''[read parameters ]'': read all parameters from permanent memory ||
{{:en:sg3:configurator_3.png?direct&600|}}
===== User interfaces settings =====
|< 475px 50px >|
^ 1 ^ LED display texts settings |
| Click to set the texts displayed on the LED display. Edit text alignment with spaces. ||
^ 2 ^ GUI display texts settings |
| Click to set the texts that appear on the graphical user interface. The text will be centered automatically. ||
{{:en:sg3:configurator_4.png?direct&600|}}
===== Events overview =====
|< 475px 50px >|
^ 1 ^ Events list |
| The last 20 event codes and data are displayed. Event #00 happened last. ||
^ 2 ^ Events legend |
| Legend for event code and data. ||
{{:en:sg3:configurator_5.png?direct&600|}}