1 | Page navigation |
---|---|
Overview page | |
Access code management page | |
Settings page | |
UI settings page | |
Events overview page | |
2 | Entry procedure steps status |
count_status | |
disinfect_status | |
temperature_status | |
code_status | |
confirmation_status | |
entry_status | |
3 | schematics |
4 | Occupation counts |
Occupation count, click to correct the actual number of visitors. | |
Occupation limits L1 / L2 | |
5 | Command buttons |
Gates Auto / Manual mode toggle | |
Alarm reset button | |
Confirmation button |
1 | Edited code |
---|---|
Click to enter the code you want to edit. | |
2 | Code type |
Click to select edited code type. Options ate L1 (level 1), L2 (level 2) or UL (unlimited). | |
3 | Access point limits |
Click to enter count limits for each access point. | |
If SG3 is the only access point in the local network, enter only in position 00 (upper left field). Enter the allowed number of entries or 255 for unlimited. | |
4 | Code activation date |
Set code activation date and time. Set all to 0 for the code that is active immediately. | |
8 | Code expiration date |
Set code expiration date and time. Set all to 0 for a code that has no validity limit. | |
6 | Edit code commands |
[ search ] = Find settings for “edit code”. |
|
[ save ] = Saves the code being edited with all settings. |
|
[ clear ] = Clear all edit settings. |
|
[ delete ] = Delete edit code from the list. |
|
7 | Codes list |
List of access codes on the controller. Clicking on the code picks up all the code values in the edit fields above. |
1 | Entry conditions |
---|---|
Count limits: set count limits for L1 and L2; 0=not limited | |
Disinfection: select if hand disinfection is required | |
Thermal scan: select if body temperature scan is required s | |
Reader: select if code reader is required | |
Confirmation: select if confirmation is required | |
2 | Entry detection settings |
Entry detection type: select entry detection type | |
Entry time-out: max time between consecutive steps | |
Confirmation time-out: max time allowed for confirmation | |
Block time-out: time for hi temperature or wrong code alert | |
After all time-outs entry procedure restarts. | |
3 | Code reader settings |
Access point ID: ID for built in access point. Used when S Gate is part of bigger Access control system, if not, leave 0. | |
Thermal scan timeout: set the time for which the system remembers the temperature scan for the code user | |
Access master code: set the code for local codes management | |
Send LAN code query: set to enable sending code queries to other access controllers on LAN | |
Process LAN code query: set to process queries from other controllers on LAN | |
4 | Auxiliary input settings |
AUX input type: set auxiliary input function to presence sensor or to call button | |
Presence / Call time-out: aux function timeout | |
5 | Gates settings |
Entry gate time-out: set entry gate signal timeout, 0=no entry gate | |
Exit gate time-out: set exit gate signal timeout, 0=no exit gate | |
6 | Alarm settings |
Alarm duration: alarm active duration time | |
Alarm beeper enabled: set to enable continuous beep during alarm | |
Reset alarm on exit: set to reset alarm when exit is detected | |
7 | Hardware overview |
Control system overview | |
Select [ Autodetect ] to find S Gate controller in LAN (when red Xes are displayed) |
|
8 | Wireless devices management |
[]wireless management: set to enable management of wireless devices | |
first icon: wireless device paired status (x=none, ✔=paired) | |
second icon: displaying wireless signal strength | |
third icon: wireless device operating as repeater (click to enable). | |
[-] : delete wireless device |
|
[+] : add wireless device |
|
9 | Controller date and time settings |
set S Gate controller date and time. | |
10 | Parameters management |
[init parameters ] : initialize all parameters to factory default values |
|
[save parameters ] : save all parameters to permanent memory |
|
[read parameters ] : read all parameters from permanent memory |
1 | LED display texts settings |
---|---|
Click to set the texts displayed on the LED display. Edit text alignment with spaces. | |
2 | GUI display texts settings |
Click to set the texts that appear on the graphical user interface. The text will be centered automatically. |