Firmware update
CyBroBinLoader software
- Download latest CyBroBinLoader.exe from www.cybrotech.com
- Run CybroBinLoader.exe
- In case Windows OS is blocking execution, click on more info and run anyway
Firmware upload
- Download latest HEMS firmware from: en:hems_v1_2_0:download
Installation and mounting
Carefully open WM-1 module and configure serial communication with jumpers. (Default configuration is 9600bps, 8N1 with normal timeout)
Place WM-1 module at least 10cm from other objects. Installation is not recommended inside metal cabinets.
- Connect RS485 terminals to WM-1 RS485 terminals
- A - A
- B - B
- C - GND
- Connect to 230V power supply
- Configure radio pairing