User Tools

Site Tools


en:hiq_hw:hc-iq-hems

HEMS controller

Advanced HEMS controller

Model number: HC-IQ-HEMS
Mounting: DIN rail, 6M, 106mm
Dimensions: 106x108x58mm

Features

  • Sources and consumers measurements:
    • 1 × Grid
    • 3 × Local power plants (PV, wind, cogeneration,…)
    • 2 × Storage system (battery)
    • 8 × Consumers
  • Load management
    • 8 × Consumers
    • Manual control
    • Manual override timer
    • Weekly timetable, 15 min resolution

Safety standards

EN 50081-1, EN 61000-6-2, EN 61131-1, EN 61131-2, EN 61000-3-2, EN 61000-3-3

Technical specification

Relay outputs: 3A/250V
Communication: Ethernet, 2x RS232, IEX bus
Nominal power rating: 24V(19-28VDC)
Power consumption typ. 4W (CPU, no external load)
typ. 5W (CPU + 8 relays, no external load)
Power output (24V at IEX-2): 2A
Weight gross: 400g
Ingress protection: IP20
Operating temperature: 0..45°C
Storage temperature: -20..75°C
Relative humidity: 0..95% n/c

Terminals

Power supply 24 V DC 24V 1 Power supply input Power supply output 19 24V Push buttons power supply
0V 2 20 0V Push buttons common - to C3
3 Digital inputs 0-7 common 21 C3 Push buttons common - to 0V
Power relay 0-4 power supply C0 4 Relay outputs 0-4 common Digital input 0 22 IX0 Managed load push-button 0
Managed load power relay 0 QX0 5 Relay output 0 Digital input 1 23 IX1 Managed load push-button 1
Managed load power relay 1 QX1 6 Relay output 1 Digital input 2 24 IX2 Managed load push-button 2
Managed load power relay 2 QX2 7 Relay output 2 Digital input 3 25 IX3 Managed load push-button 3
Managed load power relay 3 QX3 8 Relay output 3 Digital input 4 26 IX4 Managed load push-button 4
Managed load power relay 4 QX4 9 Relay output 4 Digital input 5 27 IX5 Managed load push-button 5
Power relay 5-7 power supply C1 10 Relay outputs 5-7 common Digital input 6 28 IX6 Managed load push-button 6
Managed load power relay 5 QX5 11 Relay output 5 Digital input 7 29 IX7 Managed load push-button 7
Managed load power relay 6 QX6 12 Relay output 6 Digital inputs 8-9 common 30 C4
Managed load power relay 7 QX7 13 Relay output 7 Digital input 8 / HSC A 31 IX8A
14 Digital input 8 / HSC B 32 IX9B
QW0 15 Analog output 0 HSC Z 33 Z
IW0 16 Analog input 0 Analog inputs & outputs common 34 C2
IW1 17 Analog input 1 Analog input 2 35 IW2
C2 18 Analog inputs & outputs common Analog input 3 36 IW3
en/hiq_hw/hc-iq-hems.txt · Last modified: 2019/08/14 10:49 by goran.kocjancic