Power sensor management

Default address on all power sensor is 149.
Available addresses for sensors are listed in table.

Address Power sensor position
150 Grid
154,155,156 PV
157,158 Battery storage
161..167 Consumer

Add power sensor procedure:

  • wire it to communication bus,
  • only for PM1-E-D: press and hold the push-button on the power sensor until it appears -SEt- on display,
  • it should appear in configurator as new device, click on button add next to the source or consumer where sensor should be assigned,
  • repeat procedure for next.

Note 1: adding of power sensor is supported one by one.
Note 2: For PM3-E-D is possible to set address manually according to table, before adding it to communication bus.

Without grid power sensor

  • Virtual grid PS is an option if no grid meter is used. Power, current and energy will be calculated from other power sensors.

Delete power sensor

One-phase sensors PM1-E-D

  • Make sure the “new device” is empty
  • Press the button on power-sensor until -Set- appears on the display
  • In HEMS Configurator press “del” button next to the sensor
  • After a few seconds, the sensor should appear as the “new device”
  • If desired, the sensor can be removed or it can be assigned to another device

Three-phase power-sensor

  • Make sure the “new device” is empty
  • In HEMS Configurator press “del” button next to the sensor
  • After a few seconds, the sensor should appear as the “new device”
  • If desired, the sensor can be removed or it can be assigned to another device