HEMS controller

Advanced HEMS controller

Model number: HC-IQ
Mounting: DIN rail, 6M, 106mm
Dimensions: 106x108x58mm

Safety standards

EN 50081-1, EN 61000-6-2, EN 61131-1, EN 61131-2, EN 61000-3-2, EN 61000-3-3

Technical specification

Relay outputs: 3A/250V
Communication: Ethernet, 2x RS232, IEX bus
Nominal power rating: 24V(19-28VDC)
Power consumption typ. 4W (CPU, no external load)
typ. 5W (CPU + 8 relays, no external load)
Power output (24V at IEX-2): 2A
Weight gross: 400g
Ingress protection: IP20
Operating temperature: 0..45°C
Storage temperature: -20..75°C
Relative humidity: 0..95% n/c

Terminals

Power supply 24 V DC 24V 1 Power supply input Power supply output 19 24V
0V 2 20 0V
3 Digital inputs 0-7 common 21 C3
Radiator valves power supply C0 4 Relay outputs 0-4 common Digital input 0 22 IX0
Radiator valve 0 QX0 5 Relay output 0 Digital input 1 23 IX1
Radiator valve 1 QX1 6 Relay output 1 Digital input 2 24 IX2
Radiator valve 2 QX2 7 Relay output 2 Digital input 3 25 IX3
Radiator valve 3 QX3 8 Relay output 3 Digital input 4 26 IX4
Radiator valve 4 QX4 9 Relay output 4 Digital input 5 27 IX5
Contactors power supply C1 10 Relay outputs 5-7 common Digital input 6 28 IX6
AC contactor QX5 11 Relay output 5 Digital input 7 29 IX7
Boiler contactor QX6 12 Relay output 6 Digital inputs 8-9 common 30 C4
Chiller contactor QX7 13 Relay output 7 Digital input 8 / HSC A 31 IX8A
14 Digital input 8 / HSC B 32 IX9B
QW0 15 Analog output 0 HSC Z 33 Z
IW0 16 Analog input 0 Analog inputs & outputs common 34 C2
IW1 17 Analog input 1 Analog input 2 35 IW2
C2 18 Analog inputs & outputs common Analog input 3 36 IW3

hiq_energy/hiq_hems/hardware/hems-hc-iq.1507276247.txt.gz · Last modified: by erik.bubola