CONFIGURATION MANUAL

CENTRAL CONTROL UNIT

It connects different components and communicates with the cloud.

CENTRAL CONTROL UNIT

QR CODE AND RFID CARD READER

It's for scanning the code to get in.

QR code and RFID card reader

TOF sensor

It's for counting the people.

TOF sensor

FACE SCANNER

It's for scanning the face for the mask and temperature.

Body temperature scanning device and mask wearing check

MAIN PAGE

On this menu, the user can overview system operations.

The menus can be changed on the right side of the window.

Icon border colors meaning

There are many different border colors that change if the conditions is required (or not) and if the condition is met (or not).

Icon border color meaning
Grayed outThis condition is enabled, but it can't be met right now
YellowThis condition must be met and is waiting for the person to do it
OrangeFrom now on you can enter only with L2 allowance
GreenEverything is okay, you're clear to enter
RedSomething is wrong, you must not enter
GrayThis condition doesn't have to be met because it's disabled
Status overview
Occupation status and limit count It shows occupied status and remaining count to the limit of people
Disinfector status It shows if person had applied a disinfector
Allowance status It shows if person has a fever and if he wears a facemask
Card reader It shows if the use of entry card is needed and the user's level of access
Confirmation status It shows if the receptionist had left you in and the person's level of access
Enter status It shows if person should enter or exit

This is the gate status overview.

Gate status overview
1 Door sensors It TOF sensor detects person, the entrance arrow light (right) turns on for the people coming in, or the exit arrow light (left) turns on for the people going out
2 Semaphore status If both red and green light are turned on, the entrance conditions must be met (card, face sensor, disinfector, …), if the green light is turned on you can enter, if the red light is turn on you can't enter. If the semaphore beeper is turned on along with a red light, the person must exit the building immediately. Beeper can be disabled on the System setup menu or it can be set that it resets when the person exits the building
3Gate status It shows if gates are closed or open. Smart Gate system works with all kind of gates: normal, revolving door, sliding door, …
4 Presence status It shows if the presence sensor has been triggered
5 Thermo and mask camera status It shows if person has a fever and if he wears a face mask. Two types of thermal scanner are supported. First one scans the face, checks if person is wearing a mask and measures the temperature. Doors are closed and if every condition is met, person can enter. Second scanner measures temperature of a person. Doors are opened and if it has a fever, the entrance is prevented. In the System setup menu allowance type can be set on permission mode for first instance, or it can be set on prevention mode, for second.
6 Disinfector status It shows if a person applied disinfector
7 Code reader It shows the status of access
Configuration
Set count Fix the count of total number of people counted in space, if it's found that the actual number is different from what the TOF sensor has counted
Confirm L1 If the condition for L1 access are met, the button will become enabled
Confirm L2 If the condition for L2 access are met, the button will become enabled
Reset alarm Resets alarm
Gate auto/gate opened Switches between gates opening automatically with security measures or opening manually. When they can be opened manually it usually means it's because of emergency and everyone must leave the building immediately

ACCESS SETTINGS

On this menu, the code and access status for each code can be edited.

Configuration
Edit code Manually input new user's code, alternatively you can scan it with the card scanner
Type Set user level of access, which are L1 for normal users, L2 for VIPs and UL unlimited access (employees)
Code list All the users are saved in controller. It can hold up to 100 codes. Click the code to enable editing it
Search Checks the code list for desired code, which is inputted in the edit code section. The code number and type are then returned
Save Saves the created edit code
Clear Clears the edit code and type
Delete Deletes the code from the code list

SYSTEM SETUP

When the system is connected and turned on, the technician sets these settings.

Configuration
Limit 1 This is the limit for normal access, everyone can enter. After this limit is reached, only VIPs and employees can enter (no more L1 access)
Limit 2 This is the limit for VIP access, L2 and UL can enter. After this limit is reached, only employees can enter (UL access only)
Counting type Choose if the counting of people is with digital IO or communication
Presence time-out Set how long the presence sensor is active after detecting someone
Entry gate time-out Set how long the entry doors are open after the conditions are met. If the TOF sensor detects person entering, the timer is reset
Exit gate time-out Set how long the exit doors are open after the conditions are met. If the TOF sensor detects person exiting, the timer is rest
Alarm duration Sets duration time of the alarm
Alarm beeper enabled Enable or disable alarm beeper
Reset alarm on exit Enable or disable the reset of alarm on exit
The conditions that have to be met if everything is enabled: disinfection and allowance condition must be met and then just one of other two conditions must be met, that means either reader or confirmation condition
Disinfection Sets if disinfection is necessary for user's level of access, sets time-out that triggers after check
Allowance Sets if face mask and temperature check is necessary for user's level of access, sets time-out that triggers after check
Reader Sets if scanning card on the reader is necessary for user's level of access, sets time-out that triggers after check
Confirmation Sets if receptionist confirmation is necessary for user's level of access, sets time-out that triggers after check
Allowance type If set on permission, door opens when user is clear to enter after ok allowance check, if set on prevention, door closes when users fails allowance check
Internet access
Enable push to server Enable connection to the cloud server (allow controller to send periodical push message to server) every 30 seconds
Test Send push message instantly
Reset Reset number of sent messages
Push timer Shows countdown after which the push message will be sent
Messages Number of all sent messages and number of successfully sent messages
Roundtrip Time it takes the message to get to server and the response to come back
Master code When the master code is scanned, red an green light will start flashing. If the master code is scanned, then normal cards are scanned and master code is scanned again, all the normal cards will be added to the code list (if they aren't already on it) and they will be granted L2 access. If master code is scanned and then scanned again, all the entries on code list will be deleted
Send LAN code query If scanned code is not on the code list for that device, a query will be sent to other devices in the system. If it gets the response from other device, that the code is on it's list, access is granted
Process LAN code query Enable to process code query and send back answer
LAN query timeout Set query timeout. If the device that sent query doesn't get answer in set time, it refuses access
AutodetectIt searches for other controllers in the network and opens a menu with found controllers. If the other controller is chosen, you manage this one
Parameters configuration
Init parameters Set parameters to the ones saved in permanent memory
Save parameters Save set configuration to the permanent memory
Read parameters Read parameters from the permanent memory and write them to work parameters

DISPLAY SETTINGS

Parameters configuration for alphanumeric display
Line 1
Presence Set text that will be displayed on first line when proximity detector detects someone
Advertising 01-09 Set text that will be displayed when proximity detector isn't detecting anybody
Advertising text time Set timer at which the advertising text changes
Line 2
Counters Displays number of people with L1 and with L2 access in the building
Line 3
EnterSet the text that will be displayed when person is allowed to enter
DisinfectSet the text that will be displayed when person has to disinfect hands
CameraSet the text that will be displayed when person has to look at the camera
ConfirmSet the text that will be displayed when waiting for confirmation to enter
CodeSet the text that will be displayed when person has to scan the code
OccupiedSet the text that will be displayed as long as the limit of people inside is reached
FeverSet the text that will be displayed if fever is detected
ExitSet the text that will be displayed if the person has to exit the building
Parameters configuration for graphic display
Caption
Full Set text that will be displayed if the place is full
Level 2 Set text that will be displayed when the limit of people for L1 access is reached and only people with L2 access are allowed to enter
Level 1 Set text that will be displayed if no limit of people is reached
AlarmSet text that will be displayed if alarm is triggered
WarningSet text that will be displayed if warning is triggered
Text
EnterSet the text that will be displayed when person is allowed to enter
DisinfectSet the text that will be displayed when person has to disinfect hands
CameraSet the text that will be displayed when person has to look at the camera
ConfirmSet the text that will be displayed when waiting for confirmation to enter
CodeSet the text that will be displayed when person has to scan the code
OccupiedSet the text that will be displayed as long as the limit of people inside is reached
FeverSet the text that will be displayed if fever is detected
ExitSet the text that will be displayed if the person has to exit the building