en:hems:software
This is an old revision of the document!
HEMS G2 Configurator
home
Basic system overview.
| 1. Grid | ||
|---|---|---|
| › | From grid | Tariff (LO, HI, D-LO, D-HI) and power from grid in W |
| Imported energy by tariff in Wh | ||
| ‹ | To grid | Power exported to grid in W |
| Exported energy in Wh | ||
| 2. Plants | ||
| ‹ | Produced | Produced power in W and energy in Wh |
| › | Consumed | Consumed power in W and energy in Wh |
| 3. Storage systems | ||
| ‹ | Sourced | Power in W and energy in Wh sourced from storage (battery) |
| › | Stored | Power in W and energy in Wh stored (to battery) |
| bargraph and %¹ | SOC | Battery State Of Charge |
| 4. Consumers | ||
| › | Consumed | Consumed power in W and energy in Wh |
| [] | Status | Output status for managed consumers |
| bargraph² | Analog out | Analog output value |
| click | Toggle | Click in frame toggles managed consumers output |
| long-press² | Set analog | Long press on first consumer pops-up dialog for analog value set |
| 5. Unknown source | ||
| › | Sourced | Power in W and energy in Wh from unknown source |
| |
||
| 6. Other consumers | ||
| › | Consumed | Consumed power in W and energy in Wh by other (not measured) consumers |
| 7. Temperature and humidity | ||
| Temperature | Temperature in ºC | |
| Humidity | Humidity in % RH | |
¹ only for eStore
² only for first managed consumer
power
Overview of current power distribution by source / consumer.
| 1. Sourced power |
|---|
| Sourced power for each source |
| Sums per source type |
| Total of all sourced power |
| 2. Consumed power |
| Power for each consumer |
| 3. Power distribution |
| Partial distributed power |
| 1. Sourced power distribution |
|---|
| How sourced power is consumed by each consumer |
| 2. Consumed power distribution |
| Who sources consumed power |
energy
Energy overview of a given time distributed by sources / consumers.
| 1. Sourced energy |
|---|
| Sourced energy for each source |
| Sums per source type |
| Total of all sourced energy |
| 2. Consumed energy |
| Energy for each consumer |
| 3. Energy distribution |
| Partial distributed energy |
| 4. Energy since |
| Date and time since energy is recorded |
| 5. Reset all |
| Long-press to reset all energy counters |
timetable
Weekly timetable for managed consumers.
| 1. Managed load menu |
|---|
| Switch between managed loads |
| 2. Enable checkbox |
| When un-checked timetable is not executed |
| 3. Events grid |
| Events displayed in weekly grid (15 min resolution) |
| Click to select time and set event by clicking buttons below |
| 4. Once actions (top priority timetable actions) |
| Actions are executed and then automatically cleared. |
| “Disable” action will just disable recurring action. |
| 5. Recurring actions (low priority actions) |
| Actions are executed each week. |
| 6. Analog out |
| Action to set analog output. Analog actions are recurring. |
| 7. Cloud optimization |
| When enabled (checked) cloud optimization is enabled. |
tariff
Weekly tariff timetable for grid energy per tariff distribution.
| 1. Tariff grid |
|---|
| Graphical weekly timetable with tariffs. |
| Click to select term, click-and-drag to select multiple terms. |
| 2. Low tariff |
| Set low tariff for selected terms. |
| 3. High tariff |
| Set high tariff for selected terms. |
settings
Easy and intuitive system setup.
| 1. System settings | ||
|---|---|---|
| [ autodetect ] | Click to find HEMS G2 in local network | |
| eStore | c….. | eStore serial number (automatically detected or can be entered manually). |
| [] enable | When checked HEMS will read Grid, first plant and first Storage directly from eStore (so there is no need to duplicate power-sensor). | |
| [detect] | eStore address is cleared and new eStore can be detected. | |
| HIQ Home | c….. | HIQ Home serial number (automatically detected or can be entered manually). |
| [] enable | When checked HEMS will read Grid power and energy from HIQ Home (so there is no need to duplicate power-sensor). | |
| [detect] | HIQ Home address is cleared so new can be detected. | |
| 2. Internet access | ||
| [] enable | When checked HEMS is automatically connected to HIQ Universe cloud service. Connection is initialized by HEMS system and uses UDP packets on port 8442. | |
| [test] | New “push” message is sent to server and roundtrip time is rechecked. | |
| [reset] | Clear messages counts and roundtrip time | |
| push timer | Timer in s for send “push” message to server | |
| messages | Sent “push” messages / responses counters | |
| roundtrip | Time in ms between sent push message and response. | |
| 3. Sources and Consumers settings table | ||
| SOURCES | source name | |
| icon | source icon | |
| source management | source power-sensor management | |
| message | messages regarding source power-sensor | |
| add | associate new power-sensor to source | |
| del | disassociate power-sensor from source & configure it as new power-sensor | |
| meter | source power-sensor type | |
| in/ex | power plant connected¹ | |
| new device | power-sensor configured as new one detected or wireless module configuration² | |
| Wireless setting | setting up wireless modules | |
| CONSUMERS | consumer name | |
| icon | consumer icon | |
| consumer management | consumer meter and output management | |
| message | messages regarding consumer meter and output | |
| add | associate new power-sensor or new wireless module² to consumer | |
| del | disassociate power-sensor or wireless module² from consumer & configure it as new power-sensor or new wireless module² | |
| meter | consumer meter type | |
| output | consumer output type | |
| ‹‹·›› | setting repeater mode² | |
| man. time | manged consumer manual override timer | |
| out mode | manged consumer output mode (normal or inverted) | |
| timetable | manged consumer timetable execution enabled | |
| 4. Permanent memory parameters | ||
| [init parameters] | init all parameters to default value | |
| [save parameters] | save all parameters to permanent memory | |
| [read parameters] | read all parameters from permanent memory | |
| [] autosave parameters | parameters will be automatically saved to permanent memory in 15 minutes after last parameter change | |
| 5. Backup / Restore to PC | ||
| [backup] | backup all parameters to PC | |
| [restore] | restore all parameters from PC backup | |
¹ only for the first power plant
² wireless setting must be enabled
en/hems/software.1593001348.txt.gz · Last modified: by amra.begic