en:hiq_home:methods:commissioning:firmware
Firmware
HC-IQ FW update
Download and save CyPro IDE | CyPro 2 (v2.8.0 - for HC-IQ) or Cypro 3 (v3.2.2c - for Cybro-3 and MC) |
|
Run and install it | ||
Download and open project | hc-iq-v1216.cyp (v1.2.16 - for HC-IQ) or hc-iq-v615a.cyp (v6.1.5a - for Cybro-3 and MC) |
|
Find Home Controller NAD (sticker on top or on side of HC / MC) | ||
Select Home Controller | right click on NAD | |
Enter NAD | ||
If HC does not have the latest Kernel you have to send a new one. | Tools → Kernel maintenance… | |
Send kernel to HC-IQ. | Select [Send] and then [Close] | |
Send Program | Program → Send [F9] | |
Start PLC program | Program → Start PLC [F11] |
HIQ-DC FW update
Download and unzip CybroIEXManager | CyBroIexManager | |
Download and unzip Device Controller FWs | firmware.zip | |
Start CybroIEXManager.exe | ||
Scan for Home controller | [Scan] | |
Select Home Controller (NAD number - sticker on top of HC) | ||
Scan for connected IEX Device Controllers | [Scan IEX] | |
For each connected device type open HIQ-DC FW. There can be several hardware versions. Hardware version is marked on the device or on the PCB board. Check firmware compatibility. Versions not listed there are not compatible and should not be used. | [Open] | |
Send Firmware to HIQ-DC | [Send] |
HIQ applications
en/hiq_home/methods/commissioning/firmware.txt · Last modified: 2023/01/10 15:41 by saso_santelj